+917798887373 (Mon-Fri: 9.30 AM to 6.30 PM) sales@dynafilters.com

Mobile Laminar Airflow Unit

Portable Cleanroom Workstations for Flexible Sterile Operations

In dynamic work environments where processes and space layouts change frequently, Mobile Laminar Airflow Unit offer the perfect solution for creating a flexible, particle-free zone on demand. These portable clean air stations are fitted with HEPA or ULPA filters, fan-blower assemblies, and castor wheels for mobility delivering ISO Class 5 clean air wherever needed.

Dyna’s Mobile LAF Units are ideal for pharmaceutical production areas, biotech labs, hospitals, research facilities, and electronics assembly floors where local clean air is required temporarily or in multiple locations. These units provide horizontal or vertical laminar airflow, depending on your workflow and application needs.

Mobile Trolley
Q

Product Enquiry

Q

Download Cleanroom Equipments Catalogue

13 + 12 =

Designed for ease of movement, low noise, and simple plug-and-play operation, Dyna’s mobile clean air workstations are a go-to solution for sampling, sterile transfers, inspections, temporary cleanroom setups, or as an auxiliary clean air supply during maintenance or downtime.

Dyna Sampling and Powder Dispensing Booths are engineered to provide the highest level of safety for operators and surroundings during the handling, weighing, or dispensing of hazardous or potent materials. These booths use a Reverse Laminar Air Flow (RLA) System to capture and filter airborne contaminants at the source, maintaining Class 100 (ISO 14644) air quality in the operator zone and preventing the escape of dust or powders.

Typical applications include pharmaceutical and chemical labs, R&D centers, and production facilities where containment and product integrity are critical. Dyna’s dispensing booths are also called OFCB, solvent dispensing booths, mobile RLA, or reverse LAF booths.

Key Features:

  • Class 100 Work Area – Provides ISO 14644-compliant clean air for operator and environment. Triple-Stage Filtration – H14 HEPA filter, F5 and F7 pre-filters for maximum capture.
  • Vertical Reverse Airflow – Effectively contains and removes hazardous dust at source.
  • Compact, Ergonomic Design – Space-saving, with optional worktable and side panels.
  • Feather Touch Switches – Effortless operation for all controls.
  • Digital Differential Pressure Gauge with Alarm – Alerts for filter condition and maintenance.
  • Energy Efficient LED Lighting – 500 Lux illumination for safe, clear visibility.
  • Internal Auxiliary Sockets – Power for equipment within the work area.
  • PVC Curtains – Containment curtains are provided for added isolation and cleanliness.

Specifications:

Parameter Value
Air Cleanliness Class 100
Velocity 90 FPM ± 20%
Material of Construction Exterior: SS 304 (Optional: SS 316); Side Panels: SS 304 with PUF insulated
Main Filter Minipleat HEPA, Class H14
Pre Filter Class F5 & F7
Filter Efficiency HEPA 99.997% @ 0.3 µm; Intermediate 95% @ 5 µm; Pre 90% @ 10 µm
Noise (dB) 67 ± 2
Lighting (Lux) >500 (LED)

Applications:

  • Pharmaceutical Production Lines – Flexible clean air at critical process points.
  • R&D and Analytical Labs – Mobile sample prep and inspection zones.
  • Sterile Transfer in Hospitals – During material movement or temporary setups.
  • Cleanroom Maintenance Support – Temporary clean zones during equipment service.
  • Packaging & Labeling Areas – Ensure product hygiene on moving workstations.
  • Electronics & Optical Assembly – Prevent dust entry in precision tasks.

Models:

Model Air Cleanliness Interior Dimensions (WxDxH) Exterior Dimensions (WxDxH) Power Supply
DRLAF 2*2 Class 100 710 × 725 × 1830 mm 760 × 1350 × 2200 mm 220–240 V, 50 Hz
DRLAF 3*2 Class 100 1015 × 725 × 1830 mm 1065 × 1650 × 2200 mm 220–240 V, 50 Hz
DRLAF 4*2 Class 100 1320 × 725 × 1830 mm 1370 × 1350 × 2200 mm 220–240 V, 50 Hz

 

Why Choose Dyna Mobile Laminar Airflow Units?

  • Quick deployment – Plug in and use in minutes.

  • Provides local clean zones in large or modular facilities.

  • Built with cleanroom-compatible stainless steel and low-noise fans.

  • Ideal for temporary use, validations, and gap support in permanent cleanrooms.

  • Custom configurations available for different industries and process zones.

Frequently Asked Questions (FAQs)

How mobile are these LAF units?

They are fitted with smooth-rolling, lockable castor wheels, making them fully portable across rooms or departments.

Can I use them in a non-cleanroom environment?

Yes. These units create their own localised ISO Class 5 zone, even in non-clean areas.

Are they suitable for long-term use?

Yes, with proper maintenance and timely filter replacement, they perform reliably for years.

Do you offer both vertical and horizontal models?

Yes, Dyna offers both airflow types based on your operational needs.

Looking for a flexible, sterile workspace that moves with your process?

Choose Dyna’s Mobile Laminar Airflow Units
for ISO-certified cleanliness on the go.