Cytotoxic Biosafety Cabinet
Cytotoxic Biosafety Cabinet – Ultimate Protection for Chemotherapy & Toxic Agents
Dyna Make Cytotoxic Biosafety Cabinet (BSC) is a Class II biosafety cabinet engineered specifically for safe handling of cytotoxic drugs, toxic reagents, virally infected cultures, and hazardous pharmaceutical compounds. Designed for biosafety levels 1, 2, and 3, this BSC provides operator, product, and environmental protection, ensuring contamination-free drug preparation and research applications.
At Dyna Filters, we take pride in being among the top Cytotoxic Biosafety Cabinet manufacturers in India, delivering reliable and high-performance Biological Safety Cabinets (BSC) for critical lab and industrial applications.
Product Enquiry
Download Biosure Catalogue
Key Features of Cytotoxic Biosafety Cabinet:
- EN12469-Certified – Compliance with international biosafety standards
- Designed for Hazardous Drug & Toxic Reagent Handling – Provides controlled containment for chemotherapy drugs, viral cultures, and toxic substances.
- HEPA/ULPA Filtration System Below Workbench – Additional filtration ensures extra containment for hazardous particles.
- 70% Recirculated & 30% Exhaust Airflow – Ensures safe working conditions while maintaining a controlled containment area.
- Negative Pressure Surrounds the Workspace – Prevents cross-contamination and leakage of toxic substances.
- Exhaust Flexibility – Can be vented into the room or externally via a thimble duct, depending on laboratory setup.
- Ergonomic & Energy-Efficient Design – Low noise, vibration-free operation, and LED lighting for clear visibility.
| Specification | Details |
| Biosafety Level | BSL-1, BSL-2, BSL-3 |
| Airflow System | 70% recirculated, 30% exhaust |
| Exhaust Options | Can be vented inside the room or connected to a thimble duct |
| Work Environment | ISO 5 Cleanroom Standard |
| Air Containment | Negative plenum prevents environmental fouling |
| Additional Filtration | HEPA/ULPA filtration below the workbench |
| Application-Specific Use | Cytotoxic medicines, viral cultures, toxic reagents, and hazardous drug preparation |
| Construction Material | Corrosion-resistant stainless steel |
Why Choose Dyna Cytotoxic Biosafety Cabinets?
Advanced Filtration & Airflow System for Maximum Containment
- HEPA/ULPA dual filtration ensures maximum removal of airborne cytotoxic drug particles and biohazards.
- Negative pressure plenum design prevents hazardous air leakage.
- Flexible exhaust optionsallow adaptability to various lab configurations.
Industry-Specific Compliance & Safety Standards
Dyna Cytotoxic BSCs meet and exceed international biosafety standards, including:
- EN12469-Certified – European safety compliance for biological safety cabinets.
- NSF/ANSI 49 Compliant – Ensuring safe handling of hazardous materials.
- ISO 14644 Certified – Maintains cleanroom air purity for pharmaceutical applications.
Optimized for Pharmaceutical & Clinical Applications
- Specifically designed for chemotherapy drug preparation and handling hazardous pharmaceutical compounds.
- Ergonomic design for comfortable, long-term usage in research and hospital pharmacies.
Applications – Where Cytotoxic Biosafety Cabinets Are Used

Pharmaceutical Manufacturing
Safe preparation of chemotherapy and cytotoxic drugs.

Hospital Pharmacies & Oncology Centers
Handling of hazardous medications for cancer treatment.

Toxicology & Biochemistry Labs
Containment of toxic reagents and biohazardous cultures.

Virology & Microbiology Research
Secure handling of virally infected cultures.

Clinical & Diagnostic Laboratories
Preparation and testing of hazardous biological samples.
Frequently Asked Questions (FAQs)
What is a Cytotoxic Biosafety Cabinet?
A Cytotoxic Biosafety Cabinet is a specialized Class II Type B2 cabinet designed for the safe handling and compounding of cytotoxic drugs, such as chemotherapy agents and hazardous pharmaceuticals. It offers triple protection—for personnel, product, and the environment—while ensuring contamination control during the preparation of hazardous drugs.
What makes a Cytotoxic Biosafety Cabinet different from standard Class II BSCs?
Unlike standard Class II BSCs, Cytotoxic BSCs are equipped with additional HEPA/ULPA filtration below the workbench, ensuring maximum containment of hazardous pharmaceutical particles and preventing exposure to cytotoxic drugs.
Can Cytotoxic Biosafety Cabinets be used for chemotherapy drug preparation?
Yes! These cabinets are specifically designed for the safe handling and preparation of chemotherapy drugs, ensuring operator safety and contamination control.
Does a Cytotoxic BSC require external exhaust ducting?
No, the exhaust can either be recirculated within the room or vented externally via a thimble duct. The choice depends on lab safety protocols and regulatory requirements.
Why is a dedicated cabinet required for cytotoxic drug handling?
Cytotoxic drugs are highly potent and can pose serious health risks through inhalation, skin contact, or environmental exposure. A standard biosafety cabinet is not adequate. A cytotoxic safety cabinet is engineered to meet stringent contamination control standards, including 100% external exhaust and safe change (BIBO) filter systems to prevent exposure during maintenance.
What airflow system is used in a Cytotoxic Biosafety Cabinet?
Dyna’s Cytotoxic BSC uses a Class II Type B2 airflow design:
- Vertical laminar airflow across the work surface
- HEPA-filtered downflow and exhaust
- No air recirculation; 100% of contaminated air is exhausted via a ducted system. This ensures a contamination-free work zone and eliminates chemical vapour buildup.
How does Dyna’s Cytotoxic Cabinet ensure operator safety?
Our cabinets are equipped with:
- Dual HEPA filtration (supply and exhaust)
- Safe-change filter system (BIBO)
- Negative pressure plenums
- Airflow monitoring alarms
- Chemically resistant interiors
These features prevent accidental exposure and ensure compliance with oncology and pharmaceutical compounding guidelines.
Is the cabinet compliant with international safety standards?
Yes. Dyna’s Cytotoxic Biosafety Cabinets are designed and validated to comply with:
- NSF/ANSI 49
- EN 12469
- USP <800>
- ISO 14644 cleanroom standards
- Suitable for BSL-2 and BSL-3 lab environments
What are typical applications of Cytotoxic Safety Cabinets?
These cabinets are essential for:
- Pharmacy cleanrooms
- Oncology drug preparation
- IV chemotherapy compounding
- Research involving cytotoxic agents
- Hospital and clinical laboratories
What is a BIBO system, and why is it important?
BIBO stands for Bag-In/Bag-Out, a safe-change filter system that allows filters to be replaced without contaminating the surrounding area or exposing the technician. This is crucial in handling hazardous pharmaceutical compounds and ensures operator safety during maintenance.
Can Dyna customize the cytotoxic cabinet to meet our site-specific needs?
Absolutely. Dyna offers custom sizes, ducting integration, pressure gauges, UV light options, and compliance-based features tailored to your pharmacy or hospital cleanroom environment. We also offer turnkey installation and validation support.
How often should filters be changed in a Cytotoxic BSC?
Filter replacement depends on usage, but HEPA filters generally last 2 to 3 years in high-volume pharmaceutical settings. The BIBO mechanism ensures safe replacement. Annual performance testing and airflow certification are recommended for compliance.
Why choose Dyna Filters for Cytotoxic Biosafety Cabinets?
Dyna Filters is a leading Indian manufacturer of advanced containment and cleanroom equipment, offering:
- Locally manufactured, internationally compliant cabinets
- Deep expertise in oncology and pharmaceutical safety
- AMC, validation, and filter change support
- Fast turnaround with nationwide service
- Your safety is our priority—trust Dyna for cytotoxic protection that meets global standards.
Get a Quote for Cytotoxic Biosafety Cabinets
Ensure the highest level of safety in your laboratory with Dyna Cytotoxic Biosafety Cabinets.
Contact us today for a customized quote or expert consultation.
- Request a Quote
- Call: 9370144760
- Email: sales@dynafilters.com



