When materials need to be transferred between two cleanroom areas with the same classification avoiding pressure loss during transit, a Static Pass Box offers the perfect solution. Designed without airflow or filtration, this pass box provides a physical barrier against contamination, using electromagnetic interlocks and optional UV sterilization to maintain hygiene.

Dyna’s Static Pass Boxes are built using cleanroom-grade stainless steel, with smooth interiors, toughened glass windows, and flush-mounting capability. They’re widely used in pharmaceutical production, microbiology labs, food packaging, and electronics assembly, where material movement needs to happen quickly and cleanly.

Q

Product Enquiry

Q

Download Cleanroom Equipments Catalogue

12 + 14 =

Static Pass Box Key Features:

  • No Airflow Design – Ideal for same-class cleanroom transitions.
  • Electromagnetic Door Interlock – Prevents both doors from opening at once.
  • GMP-Compliant Stainless Steel – Easy to clean, durable, and corrosion-resistant.
  • Optional UV Germicidal Lamp – Kills microbes during transfer.
  • Glass Viewing Panels – Allows visual monitoring of items inside.

Static Pass Box Specifications:

Parameter

Value

Airflow

None

Filter

None

Material

SS 304 / SS 316

Door Mechanism

Electromagnetic Interlock

UV Sterilization

Optional

Viewing Window

Acrylic / Polycarbonate / Toughened Glass

Sizes

Custom sizes available

Mounting

Wall-mounted / Floor-standing

Static Pass Box Applications:

  • Pharmaceutical Production – Transfer of clean tools, trays, and packaging.
  • Research & Testing Labs – Safe handoff of samples between controlled areas.
  • Healthcare Clean Areas – Secure item transfer without room-to-room entry.
  • Food & Cosmetic Processing Units – Barrier-based hygiene in production.
  • Electronic Assembly Units – Dust-safe movement of components.

Why Choose Dyna Static Pass Boxes?

  • Simple yet effective solution for safe intra-cleanroom material transfer.

  • Designed with cleanroom safety, durability, and visibility in mind.

  • Electromagnetic interlocks ensure safe and controlled usage.

  • Fully customizable to fit wall panels or doorways.

  • A reliable choice for ISO and GMP-certified operations.

What is a Static Pass Box?

A Static Pass Box is a contamination control device used to transfer materials between cleanroom areas and controlled environments without allowing personnel movement between zones. It acts as a physical barrier that helps minimise contamination risks while maintaining cleanroom integrity.

Static Pass Boxes are widely used in pharmaceutical manufacturing facilities, biotechnology laboratories, healthcare cleanrooms, medical device production plants, research centres, and other contamination-sensitive environments. By creating a dedicated material transfer point, the system helps reduce unnecessary personnel traffic and supports contamination control programmes.

Static Pass Box for Cleanroom Material Transfer and Contamination Control

How Does a Static Pass Box Work?

The operation of a Static Pass Box is simple but highly effective.
N

Step 1

Material is placed inside the pass box from one side.

N

Step 2

The first door is closed.

N

Step 3

The interlocking system prevents both doors from opening simultaneously.

N

Step 4

The receiving side opens the opposite door.

N

Step 5

Material is removed without direct personnel movement between rooms.

This process helps reduce contamination transfer while supporting cleanroom operating procedures.

Why Are Static Pass Boxes Important in Cleanrooms?

Personnel movement remains one of the largest sources of contamination within controlled environments. Every door opening, operator movement, and material transfer increases the risk of introducing particles into critical areas.

Static Pass Boxes help reduce this risk by creating a controlled transfer point between adjacent rooms. Instead of personnel carrying materials through multiple cleanroom zones, items can be safely transferred through the pass box while maintaining cleanroom discipline and contamination control procedures.

The result is improved workflow efficiency, reduced contamination risk, and better cleanroom performance.

Static Pass Box vs Dynamic Pass Box

Many facilities evaluate both solutions before selecting a pass box system.

Feature Static Pass Box Dynamic Pass Box
Air Filtration No HEPA Filtered
Internal Airflow No Yes
Suitable for General Material Transfer Yes Yes
Suitable for Sterile Areas Limited Preferred
Maintenance Requirement Low Moderate
Installation Cost Lower Higher

Static Pass Boxes are typically used between areas of similar cleanliness classifications. Dynamic Pass Boxes are preferred where additional contamination control through HEPA-filtered airflow is required.

Common Materials Transferred Through Static Pass Boxes

Static Pass Boxes are designed to support contamination-controlled movement of materials throughout cleanroom facilities.

Commonly transferred items include:

Raw materials
Packaging materials
Production components
Laboratory samples
Documentation
Measuring instruments
Medical consumables
Finished products

The use of dedicated transfer systems helps improve operational efficiency while reducing contamination risks.

Where Should a Static Pass Box Be Installed?

The effectiveness of a Static Pass Box depends significantly on its location within the facility.

Typical installation points include:

Between cleanroom and preparation room
Between production and packaging areas
Between warehouse staging areas and controlled environments
Between laboratories and sample preparation rooms
Between gowning areas and manufacturing zones

Correct placement supports smooth material flow and helps maintain cleanroom zoning strategies.

Common Mistakes When Selecting a Static Pass Box

Selecting the wrong pass box can create workflow and contamination control challenges.

Common mistakes include:

Choosing Incorrect Dimensions

The transfer chamber should accommodate actual material sizes.

Ignoring Door Interlocking

Interlocking is critical to prevent simultaneous door opening.

Poor Installation Location

Placement affects workflow efficiency.

Overlooking Cleaning Requirements

Pass boxes should be easy to sanitise and maintain.

Ignoring Future Expansion

Material transfer requirements often increase as production grows.

Proper planning helps avoid costly modifications later.

Benefits of Static Pass Boxes

Reduced Cross-Contamination

Creates a dedicated transfer barrier between controlled environments.

Improved Cleanroom Integrity

Reduces personnel movement between rooms.

Better Material Flow

Supports efficient transfer of materials and components.

Lower Maintenance Requirements

Simple design with minimal moving parts.

Support for GMP Compliance

Helps maintain contamination control procedures in regulated environments.

Static Pass Boxes in Pharmaceutical Manufacturing

Pharmaceutical facilities rely heavily on contamination control during material handling operations.

Static Pass Boxes help support GMP-compliant workflows by reducing unnecessary movement between cleanroom zones and providing controlled transfer of raw materials, packaging materials, laboratory samples, and production components.

They are commonly used in:

Oral solid dosage facilities
Sterile manufacturing areas
Biotechnology facilities
API manufacturing plants
Quality control laboratories

Their role is often underestimated, but they are an essential component of cleanroom contamination control infrastructure.

Why Choose Dyna Filters Static Pass Boxes?

Dyna Filters Static Pass Boxes are designed for contamination-controlled material transfer in pharmaceutical manufacturing facilities, biotechnology laboratories, healthcare cleanrooms, medical device production plants, and research environments.

Key features include:

Stainless Steel Construction
Interlocked Door Systems
Cleanroom-Compatible Design
Easy Cleaning and Maintenance
Custom Sizes Available
GMP-Friendly Construction
Integration with Cleanroom Infrastructure

Our solutions help facilities maintain cleanroom integrity, improve operational efficiency, and support contamination control objectives.

Frequently Asked Questions (FAQs)

What is a Static Pass Box used for?

It allows the transfer of materials between cleanrooms of equal classification, without active airflow.

Does it require HEPA filters or fans?

No. Static pass boxes do not use internal airflow, making them simpler and more economical.

Should I install UV sterilization in it?

It’s recommended if biological or sterile materials are being passed.

Can I get a floor-standing model instead of wall-mounted?

Yes. Dyna offers both wall-integrated and standalone models based on your layout.